The chicken house fan of Qingdao Monte New Wind Technology Co., Ltd. is specially designed for stacking high-density cage chicken houses. It can maintain excellent ventilation performance under high negative pressure cage environment and meet the requirements of cooling and ventilation of the house. The louver adopts the centrifugal opening principle to reduce the wind resistance and greatly improve the efficiency of the fan. The motor has passed the quality control test to test the new fan blade design to ensure better compression resistance and smaller air volume attenuation for the chicken house fan under the condition of low speed. Produce a higher air volume.
First, the characteristics of the chicken house fan 1, the transmission through the dynamic and static balance check 2, the louver uses the centrifugal open principle, reduce the wind resistance, greatly improve the efficiency of the fan when the fan is not running, the strong spring can close the blinds 3, each The fans have passed the separate quality inspection. 4. The fan casing and the shroud are made of strong, coated copper plywood. 2. The composition of the chicken house fan is composed of blades, blinds, window opening mechanism, motor, pulley, and Windshield, inner frame, casing, safety net and other components. When the machine is turned on, the fan is rotated by the motor, and the window opening mechanism is opened to open the blinds, and the shutters are automatically closed when the machine is stopped.
Third, the application of the chicken house fan When the outdoor temperature is higher, the temperature in the house is greater than the reference temperature, or the age of the chicken is large, when the window can not achieve the desired cooling effect, you need to consider using the fan, otherwise it will cause the chicken abnormal Onset. The exhaust volume of the fan should be determined according to the following factors. Chicks have a slow adaptation process during the transition from small to large. When the chicken is small, it is often used to start the fan with intermittent exhaust. Each time interval is 30 minutes to 60 minutes, the start time of each fan can be set according to the outside temperature, indoor temperature, and chicken age.

performance
Motor 1.0 horse 2.0 horses
Air volume @ 0Pa M3/h[cfm] 42,200[24,900] 49,500[29,100]
Air volume @ 25Pa M3/h[cfm] 35,100[20,700] 44,700[26,300]
Air volume @ 50Pa M3/h[cfm] 26,200[15,400] 36,400[21,400]
Air volume @ 0Pa M3/h/w[cfm/W] 43.7[25.7] 32.7[19.2]